Tandberg 6000MXP Manual do Utilizador Página 73

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 242
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 72
73
TANDBERG 3000 MXP & 6000 MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Conguration-type Commands – xconguration / conguration.xml
D 13887.08
MAY 2008
CameraSwUpgrade: <Auto/Off>
If set to Auto the Camera software will be automatically upgraded by the codec. If set to Off, camera software upgrade must be initiated manually by the command CameraForceUpgrade.
NOTE! If codec software is downgraded the camera software must be downgraded manually by the command CameraForceUpgrade. Applies to TANDBERG Precision HD camera only!
Example: xconguration cameraswupgrade: Auto
CameraTracking Speed: <Slow/Normal/Fast>
Sets the camera tracking speed. Camera tracking is enabled/disabled by the commands CameraTrackingStart and CameraTrackingStop.
Example: xconguration cameratracking speed: normal
Conference DefaultCall CallRate: <Tlph/1xh221/2xh221/64/128/192/256/320/384/H0/512/768/1152/1472/1920/2560/3072/4096/
Max/Auto>
Denes the default call rate to use when placing calls from the system.
NOTE! The supported call rates will depend on product type and software options.
NOTE! Auto: 384 kbps on ISDN/768 kbps on LAN
Example: xconguration conference defaultcall callrate: 320
The DefaultCall settings specify
call properties to use if proper-
ties are not specied directly
when placing the call.
Conference DefaultCall Restrict: <On/Off>
A restricted call uses 56kbps channels rather than the default unrestricted 64kbps channels. Some older networks
(primarily in the USA) do not support 64kbps channels and require the use of restricted 56kbps calls. By default, the
system will dial an unrestricted call and downspeed to 56kbps if necessary.
To force a restricted call, choose Restrict (56k) On.
Example: xconguration conference defaultcall restrict: off
Conference DefaultCall NetProle: <1..7>
Selects default NetProle. Please refer to the NetProle conguration for further details on the supported NetProles.
Example: xconguration conference defaultcall netprole: 3
Conference H323Alias E164: <E164: 0, 30>
Denes the E164 alias for the system. Valid characters are 0-9,
*
and #.
Example: xconguration conference h323alias e164: 666666
The aliases dene the telephone
numbers for the unit, i.e. num-
bers to call to reach the unit.
The system can register both an
E164 alias, which can only con-
tain digits (including
*
,
#
) and
an ID, which can also contain
letters.
Conference H323Alias ID: <S: 0, 49>
Denes the H323Alias ID for the system. If no ID is specied the system will use the SystemUnit Name as
H323Alias ID.
Example: xconguration conference h323alias id: MyH323AliasId
Conference PeriodicIntra: <0..1000>
Use this setting to generate a new intra frame with a congurable interval. Use this setting with caution since it in a normal network will de-
crease the video quality. The default value is set to 0 which means off. If you congure it to 10 it will send an intra every 10th second.
Example: xconguration conference periodicintra: 0